Trillium™ 5000.

|
Product Overview
Choose
Power that’s Easy to Use
Our Trillium 5000 Holter Recorder and Trillium Gold Holter
Analysis Software form a complete and comprehensive Holter
Monitoring System that is both powerful and easy to use..
Discover
the Value Leader in Holter
Our compact Trillium 5000 Holter Recorder provides superior
performance and comes with a two year warranty and unlimited
toll free technical support from our Holter knowledgeable
staff.
Provide
the Best Possible Care
Our Trillium Gold Holter Analysis Software provides flexible
and accurate analysis, expanded functionality, powerful editing
capabilities, and configurable and editable reports to give
you the information you need to provide the best possible
patient care.
|
Product Specifications:
Channels:
2 or 3
Recording
Time: 24 or 48 Hours
Recording:
Continuous (Full Disclosure)
Memory:
Non-volatile Flash-Card
Resolution:
10-bit sampling
Sample
Rate: 512 samples per second
per channel
Frequency
Response: 0.05 Hz – 60 Hz
Gain
Settings: 1/2X, 1X, and 2X
Power
Requirements: (1) AA Alkaline IEC-LR6
Overall
size: 2.78 x 3.75 x 0.78 inches
(88.9 x 162.6 x 24.1 mm)
Weight
Including Batteries: 4 ounces
(112 grams)
Operating
Temperature: 32° F to 113° F
(0° C to 45° C)
Non-operating
Temperature: -4° F to 149° F
(-20° C to 65° C)
Operating
Humidity: 10% to 95%
(non-condensing)
Non-operating
Humidity: 5% to 95%
(non-condensing)
Patient
Cable: 5 or 7 Lead
Signal
Verification: LCD Display -
ECG Display on LCD
Five
button keypad operation with LCD Display
Meets
the ANSI/AAMI standard for
ambulatory electrocardiographs (EC38)
including pacemaker and use for infants
Unlimited
Toll Free Technical Support
Pacemaker Detection / Reporting
Superimposition:
One
or two beats
Variable
rate scanning
One beat
or one minute jog-back / jog-forward
Automatic
jog-back based on user
reaction time
R-R histogram
or tachogram side display
Q-T Interval Measurement:
Graph
Superimposition
Editing
Raw
Corrected
Auto
Q-T Calipers
R-R Interval Measurement:
Shortest
and Longest R-R Interval
Time-domain
Heart Rate Variability statistics
On-Screen Calipers:
Measure
time intervals or ST level
Caliper
Interval Repeat
Calipers
can be saved with strip
Show
Rate Measurements
Show
R-R Interval Measurements
Report:
Memory
Card Data (MCD) File Storage
Memory
Card Report (MCR) File Storage
Copy
/ paste text into Windows clipboard
Copy
/ paste graphs into Windows clipboard
Customize
Report Layout
One Page
Report
Cover Page:
Patient
Information
Medications
/ Symptoms
Print
Logo
Physician
Information
Referring
Physician Information
Conclusions
Parameter
Settings
ICD-9
CM Drop Down Box
Narrative Summary:
Initial
Signal Quality
Total
QRS Complexes
Average,
Maximum, and Minimum Heart Rate
Total
Ventricular Ectopic Beats (VE)
Isolated
Ventricular Ectopic Beats
Bigeminy,
duration
Trigeminy
episodes
Couplets
(VE Pairs)
Ventricular
Runs, duration, longest and fastest
Idio-ventricular
Rhythm (<100 BPM)
Total
Supraventricular Ectopic Beats (SVE)
Isolated
Supraventricular Ectopic Beats
SVE Pairs
SV Bigeminy
SV Trigeminy
Supraventricular
Tachycardia (SVT),
duration, longest and fastest
Irregular
Rhythm, duration
Tachycardia,
duration
Bradycardia,
duration
Pauses
(Asystole)
Longest
Pause (Asystole)
ST Depression
/ Elevation
Patient
Events
Pacemaker
Analysis (Total Paced Beats,
Failure to Capture, Failure to Sense)
Hourly Summary:
Customizable
Average,
Maximum, and Minimum Heart Rate
Isolated
Ventricular Ectopic Beats
Bigeminy
Trigeminy
Couplets
(VE pairs)
Ventricular
Runs
Isolated
Supraventricular Ectopic Beats
SVE Pairs
SV Bigeminy
SV Trigeminy
Supraventricular
Tachycardia (SVT)
Tachycardia
Irregular
Rhythm
Bradycardia
Pauses
(Asystole)
ST Depression
/ Elevation
Patient
Events
Graphs:
Heart
Rate
Ventricular
Ectopics
Ventricular
Runs
Supraventricular
Ectopics
Supraventricular
Tachycardia
Artifact
Index (2 or 3 channel)
ST Level
(2 or 3 channel)
Normal
R-R Histogram
Abnormal
R-R Histogram
Pacer
Rate
Pacer
R-R Histogram
Q-T Graph
Pause
Graph
Ventricular Forms:
Beat
Count and Sample of up to
32 Ventricular Forms
Beat
Count and Sample of up to
32 Normal Forms
Reclassify
Forms by Prematurity and Shape
Turn
off a channel
Strips:
Automatic
Report Strips in full-scale (25 mm/
sec) or mini-scale (8.5 mm/sec) format
Automatic
Report Strips 8, 18, or 32 per page
Strip
List
Extract
strip from any time in the
monitoring period
Extract
all strips for an episode type
Full Disclosure:
Print
in 1 Hour Increments
15, 30,
or 60 seconds per line
1 Channel
Only
Any combination
of 2 or 3 channels
Patient
event indicated by circle
Information
at end of line (HR, VEs, ST, SVEs)
Alternate Outputs:
Graphs
bitmapped to clipboard
Text
bitmapped to clipboard
Analysis Algorithm:
Forest
Medical eidos™ Holter Algorithm
Adjustment
for Atrial Fibrillation /
Irregular Rhythm sensitivity
Pediatrics:
Rate
Parameter Settings
High
Rate Algorithm
Under
20 kg Patients
Click here to see